Quantcast
Channel: SCN: Message List
Viewing all articles
Browse latest Browse all 8594

Re: caller 90 contains an error message.do not have authorization to extract from datasource 80xxxx,component DM

$
0
0

Hi,

 

Replicate the data source in BW.

Run the program RS_TRANSTRU_ACTIVATE_ALL for the source system. (3.X)

 

Goto transaction SE38, Run the program RSDS_DATASOURCE_ACTIVATE_ALL. (7.0)

Give your Data source name, and source system and check the check box for "Only Inactive objects".

This will activate the given data source.

 

Try to schedule the info package for the data source which you have activated now.

IF info package runs through, Repeat the process for all data sources ie unchecked the check box, which means it will activate all data sources for the source system.

 

check the autihosization your basis team using t code- SU53.

 

Check the job in SM37.

 

Thanks,

Phani.